Lutronic eCO2 Fractional Laser
$8,000.00
The Lutronic eCo2 – Ablative Co2 Fractional Laser features the patented Controlled Chaos Technology (CCT), an algorithm to pseudo-randomly deliver each micro laser beam and by placing maximum distance between sequential beams the system eliminates cross thermal diffusion between adjacent Micro-ablative Columns (MACs).
Lutronic eCO2
The CO2 laser beam heats and vaporizes the skin tissue , instantly removing the superficial layers of the skin. Each fractional micro spot creates a thermal zone. Intact cells around the treated area help the healing process . This process induces cell regeneration. The contraction is immediate and the structural improvement of the skin you start to see about one week after the procedure .
The fibroblasts respond in a natural way by producing collagen, elastin and glycosaminoglycans , which begin the process of restructuring of the skin . eCO2 combines the laser beam to 10,600 nm with 3 different types of tip , with the possibility to have a penetration depth of from 50 microns to 2.4 mm . Using a proprietary algorithm called the patented Controlled Chaos Technology ( CCT) , eCO2 distributes the treated every laser beam as far as possible from the previous one , in order to maximize the dissipation of heat. This method results in the optimization of the fractional thermal relaxation time of the tissue, with a consequent healing process faster and less painful
Specifications :
- Laser Type:Ablative Fractional Resurfacing (AFR)
- Beam Delivery Method:Articulated Arm with Scanner or Convetional Handpiece
- Medium & Method of Generation:Seall Off CO2 RF Mudule Laser
- Wavelength:10,600 nm
- CO2 RF Module Maximum Power: Maximum 30 Watt at Continuous Wave
- Fractional Scanner Handpiece: User Mode:Static (Stamping) / Dynamic (Air Brushing)
- Tip:120, 300, 1000 um Spot Sizes
- Pulse Energy:2 mJ – 240 mJ
- Pulse Rate:10Hz to 200 Hz
- Density:25 – 400 Spots / cm2
- Scan Area:Max.14 x 14 mm
- Scan Shapes:Square, Rectangle, Oval, Triangle, Point Beam
- Normal Handpiece: User Mode:Char Free (Ultra Pulse) / Super Pulse / CW
- Pulse Rate:Char Free (Ultra Pulse) – 1 Hz to 700 Hz; Super Pulse – 1 Hz – 550 Hz
- Pulse Width:Char Free (Ultra Pulse) – 40 us to 1000 us; Super Pulse – 1 ms – 5 ms
- CW:ON Time – Cont. 0.01 s – 1.0 s
- CW:OFF Time – SINGLE 0.001 s – 1.0 s
- Adjustable Spot Size:0.2 – 1.0 mm
- User Interface:Touch Screen with Flash Technology 7 inch LCD Screen
- Dimensions EXCLUDES ARM: 360 mm (W) x 450 mm (L) x 1000 mm (H)
- Dimensions WITH ARM: 360 mm (W) x 450 mm (L) x 1870 mm (H)
- Weight:77 lbs. (35 kg)
- Cooling:Air Cooling
MINIMAL DOWNTIME & LESS DISCOMFORT
- Skin Tightening
- Wrinkles, Rhytids & Fine Lines
- Pigmented Lesions & Lentigines
- Scars
- Textural Irregularities
- Transepidermal Drug Delivery
- Dyschromia
- Solar/Actinic Elastosis
- Syringoma
- Vaporization, Incision & Excision Capabilities
Lutronic eCO2 Technical Data
Manufacturer | Lutronic |
---|---|
Dimensions | 36 cm (W) x 45 cm (L) x 187 cm (H) |
Weight(excluding the arm) | 48 kg |
Cooling method | Air cooling |
Electrical rating | Single phase AC100-120V or AC220-230V, 50/60Hz (FUSE 250V/6.3A), Power consumption: 800VA |
MINIMAL DOWNTIME, IMPROVED PATIENT COMFORT, INCREASED SAFETY
The eCO2 features the patented Controlled Chaos Technology (CCT™), an algorithm to pseudo-randomly deliver each micro laser beam and by placing maximum distance between sequential beams the system eliminates cross thermal diffusion between adjacent Micro-ablative Columns (MACs).
This allows the tissue to maximize heat dissipation between shots. The result is an increased safety profile with a reduction in post-operative discomfort and faster healing time leading to unparalleled fractional resurfacing results.
ULTIMATE CONTROL OVER ENERGY DELIVERY
DYNAMIC MODE
Dynamic Mode completely eliminates the checkerboard look of other CO2 systems and provides clinicians with a more comfortable operation by allowing the user to ‘Air Brush’ the energy. Whether you are treating large areas or just feathering to eliminate demarcation lines, Dynamic Mode provides your patients with a more natural look.
STATIC MODE
Static Mode allows for traditional ‘Stamping’ which allows users to treat scanned areas of 14 x 14 mm with selectable density options to enable precise delivery of laser energy without the need for multiple passes other systems require.
QUICK-CHANGE TIPS WITH AUTO-RECOGNITION
From ultra-deep to superficial ablation, the eCO2 has the features you need to address a broad range of clinical conditions. The ultra-fast quick change tips come in a choice of three spot sizes, 120 and 300 μm, allowing you on-the-fly customized treatments. The eCO2’s tip auto-recognition feature automatically changes treatment settings to adjust for the change in spot size. Combined together, the advanced technology, quick-change tips and safety features ensure the ultimate control for the best outcomes.
120 µm Spot Size
• Scars
• Deep Wrinkles
• Tightening
300 µm Spot Size
• Large Pores
• Skin Texture
• Luminosity
500 µm Spot Size
• Skin Tone
• Texture
• Luminosity
The Lutronic eCO2 sets it self apart from the competition with ultra deep ablation depths. eCO2 is proven to deliver up to 2.4 mm of ablation depth.
Reviews